“I have an older Hydro-Mac skid loader and had a problem shearing the roll pins in the machine’s hydrostatic pumps. To solve the problem, I mounted stops on the pins’ forward and reverse travel. Now the arms don’t go far enough in to shear the pins before they reach the end of their travel inside the pump.”
Reproduced from the published FARM SHOW entry. Prices, coupons, availability and contact details are historical, not current offers. Reader methods are not universal instructions: follow manufacturer guidance, proper supports and safety practices, and consult a qualified professional when needed.
Comments and votes